4,838 research outputs found

    Calculation of sidewall boundary-layer parameters from rake measurements for the Langley 0.3-meter transonic cryogenic tunnel

    Get PDF
    Correction of airfoil data for sidewall boundary-layer effects requires a knowledge of the boundary-layer displacement thickness and the shape factor with the tunnel empty. To facilitate calculation of these quantities under various test conditions for the Langley 0.3 m Transonic Cryogenic Tunnel, a computer program was written. This program reads the various tunnel parameters and the boundary-layer rake total head pressure measurements directly from the Engineering Unit tapes to calculate the required sidewall boundary-layer parameters. Details of the method along with the results for a sample case are presented

    Modifications to Langley 0.3-m TCT adaptive wall software for heavy gas test medium, phase 1 studies

    Get PDF
    The scheme for two-dimensional wall adaptation with sulfur hexafluoride (SF6) as test gas in the NASA Langley Research Center 0.3-m Transonic Cryogenic Tunnel (0.3-m TCT) is presented. A unified version of the wall adaptation software has been developed to function in a dual gas operation mode (nitrogen or SF6). The feature of ideal gas calculations for nitrogen operation is retained. For SF6 operation, real gas properties have been computed using the departure function technique. Installation of the software on the 0.3-m TCT ModComp-A computer and preliminary validation with nitrogen operation were found to be satisfactory. Further validation and improvements to the software will be undertaken when the 0.3-m TCT is ready for operation with SF6 gas

    Corrections for attached sidewall boundary-layer effects in 2-dimensional airfoil testing

    Get PDF
    The problems of sidewall boundary-layer effects in airfoil testing is treated by considering the changes in the flow area due to boundary-layer thinning under the influence of the airfoil flowfield. Using von Karman's momentum integral equation, it is shown that the sidewall boundary-layer thickness in the region of the airfoil can reduce to about half the undisturbed value under the conditions prevailing in testing of supercritical airfoils. A Mach number correction due to this increased width of the flow passage is proposed. Using the small disturbance approximation, the effect of the sidewall boundary-layers is shown to be equivalent to a change in the test Mach number and also in the airfoil thickness. Comparison of the results of this approach with other similarity rules and correlation of the experimental data demonstrate the applicability of the analysis presented from low speeds to transonic speeds

    Performance of the active sidewall boundary-layer removal system for the Langley 0.3-meter Transonic Cryogenic Tunnel

    Get PDF
    A performance evaluation of an active sidewall boundary-layer removal system for the Langley 0.3-m Transonic Cryogenic Tunnel (TCT) was evaluated in 1988. This system uses a compressor and two throttling digital valves to control the boundary-layer mass flow removal from the tunnel. The compressor operates near the maximum pressure ratio for all conditions. The system uses a surge prevention and flow recirculation scheme. A microprocessor based controller is used to provide the necessary mass flow and compressor pressure ratio control. Initial tests on the system indicated problems in realizing smooth mass flow control while running the compressor at high speed and high pressure ratios. An alternate method has been conceived to realize boundary-layer mass flow control which avoids the recirculation of the compressor mass flow and operation near the compressor surge point. This scheme is based on varying the speed of the compressor for a sufficient pressure ratio to provide needed mass flow removal. The system has a mass flow removal capability of about 10 percent of test section flow at M = 0.3 and 4 percent at M = 0.8. The system performance has been evaluated in the form of the compressor map, and compressor tunnel interface characteristics covering most of the 0.3-m TCT operational envelope

    A feasibility study of using Langley 0.3-m transonic cryogenic tunnel sidewall boundary-layer removal system for heavy gas testing

    Get PDF
    This report presents the results of a preliminary study for using the 0.3-m Transonic Cryogenic Tunnel sidewall boundary-layer removal system with heavy gas sulfur hexafluoride as the test medium. It is shown that the drive motor speed/power of the existing system and the additional heat load on the tunnel heat exchanger are the major problems limiting the boundary-layer removal system performance. Overcoming these problems can provide the capability to remove about 1.5 percent of the test section mass flow at Mach number M = 0.8 and about 5 percent at M = 0.25. Previous studies have shown that these boundary-layer mass flow removal rates can reduce the boundary-layer thickness by a factor of two at the model station. Also the effect of upstream boundary-layer removal on the airfoil test data is not likely to be significant under high lifting conditions. Near design conditions, corrections to the test Mach number may be necessary to account for sidewall boundary-layer effects

    Ion composition and drift observations in the nighttime equatorial ionosphere

    Get PDF
    The first in situ measurements of ion composition in the nighttime equatorial E and F region ionospheres (90-300 km) are presented and discussed. These profiles were obtained by two rocket-borne ion mass spectrometers launched from Thumba, India on March 9-10, 1970 at solar zenith angles of 112 deg and 165 deg. Ionosonde data established that the composition was measured at times bounding a period of F region downward drift. During this period the ions O(+) and N(+) were enhanced by one to three orders of magnitude between 220 and 300 km. Below the drift region (200 km), O(+) ceased to be the major ionic constituent, but the concentrations of O(+) and N(+) remained larger than predicted from known radiation sources and loss processes. Here also, both the O2(+) and NO(+) profiles retained nearly the same shape and magnitude throughout the night in agreement with theories assuming scattered UV radiation to be the maintaining source. Light metallic ions including Mg(+), Na(+) and possibly Si(+) were observed to altitude approaching 300 km, while the heavier ions Ca(+) and K(+) were seen in reduced quantity to 200 km. All metal ion profiles exhibited changes which can be ascribed to vertical drifting

    A study of residual interference effects in adaptive wall testing of a 7-inch chord CAST-10-2/DOA 2 airfoil model

    Get PDF
    The residual interferences present in the testing of a CAST10-2/DOA2 airfoil model in the Langley 0.3 m Transonic Cryogenic Tunnel (0.3 m TCT) is examined. The 7.1 inch chord airfoil model was tested in the 0.3 m TCT adaptive wall test section with a nominal 13 inch square cross section. The test data obtained on the same model during different tunnel entries showed different levels of residual interference. The present study shows that for valid comparison of the test data from adaptive wall tunnels, it is necessary to account for residual interferences, in particular the blockage correction to the Mach number

    A simplified fourwall interference assessment procedure for airfoil data obtained in the Langley 0.3-meter transonic cryogenic tunnel

    Get PDF
    A simplified fourwall interference assessment method has been described, and a computer program developed to facilitate correction of the airfoil data obtained in the Langley 0.3-m Transonic Cryogenic Tunnel (TCT). The procedure adopted is to first apply a blockage correction due to sidewall boundary-layer effects by various methods. The sidewall boundary-layer corrected data are then used to calculate the top and bottom wall interference effects by the method of Capallier, Chevallier and Bouinol, using the measured wall pressure distribution and the model force coefficients. The interference corrections obtained by the present method have been compared with other methods and found to give good agreement for the experimental data obtained in the TCT with slotted top and bottom walls

    Effect of aspect ratio on sidewall boundary-layer influence in two-dimensional airfoil testing

    Get PDF
    The effect of sidewall boundary layers in airfoil testing in two-dimensional wind tunnels is investigated. The non-linear crossflow velocity variation induced because of the changes in the sidewall boundary-layer thickness is represented by the flow between a wavy wall and a straight wall. Using this flow model, a correction for the sidewall boundary-layer effects is derived in terms of the undisturbed sidewall boundary-layer properties, the test Mach number and the airfoil aspect ratio. Application of the proposed correction to available experimental data showed good correlation for the shock location and pressure distribution on airfoils

    Sidewall boundary-layer measurements with upstream suction in the Langley 0.3-meter transonic cryogenic tunnel

    Get PDF
    The Langley 0.3 Meter Transonic Cryogenic Tunnel has provision for boundary removal from the sidewalls to reduce sidewall interference effects on the test data. The tests carried out to determine the change in the empty test section sidewall boundary layer thickness at the model station with upstream boundary layer mass removal are described. The boundary layer measurements showed that the upstream removal region is effective in reducing the boundary layer thickness at the model station. The boundary layer displacement thickness reduced from about 1.2 percent to about .4 percent of the test section width. The boundary layer velocity profiles followed a power law variation in the outer region and showed good correlation when plotted in terms of boundary layer momentum thickness
    corecore